Product Filters

Laboratory Balances for Analytical and Precision Weighing

 

Laboratory balances are high-accuracy weighing instruments used to measure the mass of reagents, samples, and materials in research, quality control, and pharmaceutical applications. Analytical balances offer readability to 0.1 mg (0.0001 g) for small-mass, high-precision work; precision (top-loading) balances cover higher capacities with readability of 1 mg to 0.1 g for routine weighing, formulation, and sample preparation.

MBP is a registered vendor for Howard Hughes Medical Institute, Vanderbilt University, and MD Anderson Cancer Center, and provides purchase order procurement for laboratory balances for research institutions across the USA and Canada. Request a quote for laboratory balances for analytical weighing, precision measurements, and sample preparation by contacting customerservice@mbpinc.net.

Laboratory Balances

Per Page:
Sort By:
Accuris™ Analytical Balance Series
List Price:
USD2,950.69 - USD3,631.02
Online Price:
USD2,107.64 - USD2,593.58
Your Price:
Accuris™ Compact Balance Series
List Price:
USD470.81 - USD819.52
Online Price:
USD336.29 - USD585.37
Your Price:
Accuris™ Mini Balance
List Price:
USD84.93 - USD91.01
Online Price:
USD60.66 - USD65.01
Your Price:
Accuris™ Precision Balance Series
List Price:
USD1,621.94 - USD2,395.42
Online Price:
USD1,158.53 - USD1,711.01
Your Price:
GBA Analytical Balance Series
List Price:
USD3,798.21 - USD8,579.43
Online Price:
USD2,713.01 - USD6,128.17
Your Price:
GBA Precision Balance Series
List Price:
USD3,467.31 - USD4,773.10
Online Price:
USD2,476.65 - USD3,409.36
Your Price:
GBB Portable Precision Balance Series
List Price:
USD617.39 - USD1,375.49
Online Price:
USD440.99 - USD982.49
Your Price:
GBBH Portable Precision Balance Series
List Price:
USD832.58 - USD2,952.60
Online Price:
USD594.70 - USD2,109.00
Your Price:
GBP High Capacity Portable Precision Balance Series - External Calibration
List Price:
USD1,570.86 - USD2,638.32
Online Price:
USD1,122.05 - USD1,884.52
Your Price:
GBP High Capacity Portable Precision Balance Series - Internal Calibration
List Price:
USD2,358.49 - USD2,886.37
Online Price:
USD1,684.64 - USD2,061.69
Your Price:
GBP Portable Precision Balance Series
List Price:
USD1,531.10 - USD2,207.80
Online Price:
USD1,093.64 - USD1,577.00
Your Price:
GBT High Capacity Touchscreen Balance Series - External Calibration
List Price:
USD3,020.43 - USD3,334.84
Online Price:
USD2,157.45 - USD2,382.03
Your Price:

Showing 1 to 12 of 29 results

What Are Laboratory Balances?

 

Laboratory balances are precision instruments that determine the mass of a substance by comparing it against a known reference or by measuring the force required to restore an electromagnetic or strain gauge sensor to equilibrium. The two principal types in research laboratories are analytical balances and precision (top-loading) balances. Analytical balances, with readability of 0.1 mg (one-tenth of a milligram, expressed as 0.0001 g), are enclosed in a draft shield to eliminate the effect of air currents on sensitive measurements and are used for quantitative chemical analysis, pharmaceutical formulation, reagent preparation requiring accurate stoichiometry, and trace sample weighing. Precision balances have lower readability (1 mg to 0.1 g) but higher capacity (up to several kilograms), handle larger samples without a draft shield, and are used for routine weighing in general chemistry, media preparation, and quality control workflows. A third category, microbalances (readability 0.001 mg or finer), serves specialized applications including filter gravimetry, pharmaceutical microsampling, and material science. Choose an analytical balance (0.1 mg readability) when mass accuracy matters to the fourth decimal place; choose a precision balance for routine weighing where 1 mg resolution is sufficient and capacity above 300 g is needed.

 

What you will find:

 

  • Analytical Balances: Precision devices created for measuring small weights below a milligram, equipped with enclosed compartments to minimize external disturbances.

  • Precision Balances: Multifunctional weighing systems that provide high-capacity performance while ensuring the accuracy required for everyday laboratory and industrial weighing.

  • Compact Balances: Portable weighing devices with a small footprint designed for environments with limited space and less demanding measurement requirements.

  • Mini Balancess: Compact, battery-powered scales created for rapid, portable weighing during fieldwork or educational environments.

  • High Capacity Balances: Strong systems designed for assessing substantial bulk samples or industrial substances while maintaining precision.

  • Moisture Analyzers: Specific devices that employ heating components and accurate weighing to assess the moisture level in different samples.

  • Laboratory Balance Accessories: Crucial support equipment that features anti-static ionizers, serial printers, and pipette calibration systems for improved balance efficiency.

 

How to Choose a Laboratory Balance

 

Readability and accuracy

Readability is the smallest mass increment the balance can display. An analytical balance with 0.1 mg (0.0001 g) readability is the standard for quantitative chemistry, whereas a precision balance with 1 mg (0.001 g) readability suffices for routine sample preparation and formulation. Accuracy is distinct from readability; it describes how close the displayed value is to the true mass. Calibrated balances traceable to national standards (NIST in the USA) provide accuracy verification. Do not conflate the two: a balance with fine readability can still have poor accuracy if uncalibrated.

Capacity

Analytical balances typically offer a maximum capacity from 100 g to 520 g. Precision balances cover 120 g to several kilograms. Choose capacity based on the maximum sample plus container mass to be weighed: weighing a 250 g vessel on a 200 g capacity balance is not possible and overloads the weighing cell. Most analytical balances include overload protection, but repeated overloading shortens the weighing cell service life.

Internal vs. external calibration

Balances with internal calibration have a built-in calibration weight that the instrument deploys automatically (triggered by a temperature change, time interval, or user command) to verify and correct its calibration without operator involvement. External calibration requires the operator to place a certified calibration weight on the pan and follow a manual procedure. For regulated environments (GLP, GMP, ISO 17025), internal calibration reduces human error in the calibration process and provides automatic documentation.

Draft shield design

Analytical balances require a draft shield (enclosure around the weighing pan) to prevent air currents from introducing measurement noise. Motorized sliding-door draft shields (available on advanced models) open and close automatically during sample placement, reducing operator contact time and improving repeatability. Manual draft shields with sliding or hinged doors are standard on most models. Confirm door opening dimensions fit the sample containers used in your workflow.

Connectivity and GLP compliance

Digital balances with RS-232, USB, or Ethernet connectivity output weight data directly to LIMS, laboratory notebooks, or printers, eliminating manual transcription errors. Good Laboratory Practice (GLP) compliance features include automatic date and time stamping of weighing records, unique instrument ID in the printout, and traceability documentation for calibration. These features are required in pharmaceutical QC and accredited analytical laboratories.

 

Specifications Context

 

Proper calibration and verification are essential for maintaining weighing accuracy and repeatability. MBP offers analytical, precision, semi-micro, compact, portable, and high-capacity balances with internal or external calibration options to support a wide range of laboratory applications. For routine balance verification and calibration procedures, Class E2, F1, and F2 calibration weights are available. Always follow the balance manufacturer's calibration and operating recommendations to ensure reliable measurement performance.

 

Require support in selecting the appropriate readability for your analytical tasks or assistance in locating the right high-capacity model? The MBP team is available to help—contact us now for a personalized estimate.

FAQ

An analytical balance has a readability of 0.1 mg (0.0001 g) and is enclosed in a draft shield to eliminate air current effects; it is used for quantitative chemical analysis, pharmaceutical formulation, and any weighing requiring accuracy to the fourth decimal place in grams. A precision balance (top-loading balance) has readability of 1 mg to 0.1 g, higher capacity (up to several kilograms), and does not require a draft shield; it is used for routine weighing, media preparation, and general lab formulation where microgram accuracy is not required.
Required readability depends on the mass accuracy the application demands. Quantitative chemical analysis, stoichiometric reagent preparation, and pharmaceutical microformulation require analytical balance readability of 0.1 mg (0.0001 g). Routine sample preparation, buffer preparation, and QC formulation of larger quantities are adequately served by a precision balance with a readability of 1 mg (0.001 g). Microbalances with 0.001 mg (0.000001 g) readability are specified for ultra-trace work such as particulate matter filter gravimetry and nanomaterial weighing.
Analytical balances measure mass at 0.1 mg sensitivity, which means an air current of less than 0.1 m/s can introduce more than 0.1 mg of measurement error by exerting a force on the sample pan. A draft shield (glass or polycarbonate enclosure) surrounding the pan eliminates this effect by blocking air movement around the sample. Motorized draft shields that open and close automatically reduce the time the enclosure is open during sample placement and further improve repeatability compared to manual sliding door designs.
Internal calibration uses a built-in calibration weight stored inside the balance that is deployed automatically when the instrument detects a temperature change, at timed intervals, or on user command. The balance compares its reading to the known mass, corrects any offset, and documents the calibration event. This eliminates the need for the operator to handle external calibration weights and reduces calibration error in busy labs. For GLP, GMP, and ISO 17025 accredited workflows, internal calibration with automatic documentation is strongly preferred over manual external calibration.
For balances with internal calibration, activate the auto-calibration function according to the manufacturer's procedure; the balance deploys its internal weight, verifies response, and records the calibration. For external calibration, place a certified calibration weight (OIML or ASTM traceable, appropriate to the balance capacity) on the pan, follow the manufacturer's calibration procedure, and record the result in the equipment logbook with date, operator ID, weight identity, and environmental conditions. Calibration should be performed after relocation, after significant temperature change, and at a minimum on a scheduled periodic basis.
Analytical balances should be placed on a vibration-isolated surface (dedicated balance table or anti-vibration mat) away from air vents, windows, and high-traffic areas. The operating temperature range is typically 10 degrees C to 30 degrees C, with temperature stability better than 1 degree C per minute to prevent measurement drift. Allow 15 to 30 minutes of equilibration time after moving or powering on the balance before performing critical measurements. Humidity above 80% relative humidity can affect the balance mechanism and should be avoided.
Capacity must exceed the combined mass of the sample and any container or weighing vessel placed on the pan. Analytical balances cover 100 g to 520 g -- adequate for small sample weighing in standard lab glassware or plastic weigh boats. Precision balances with 1 kg to 6 kg capacity handle larger reagent preparations, media batches, and packaged materials. Never exceed the stated maximum capacity; overloading damages the weighing cell and requires costly repair or replacement.
Yes. MBP provides purchase order procurement for laboratory balances for research institutions across the USA and Canada. MBP is a registered vendor for Howard Hughes Medical Institute, Vanderbilt University, and MD Anderson Cancer Center. Contact MBP via the contact page or Quick Order portal with your required readability, capacity, and connectivity specifications for a quote and lead time.
We provide the highest quality of products and anytime customer service.
Featured Categories
    online payment
    online payment
    fast delivery
    fast delivery
    technical support
    technical support
    24/7 support
    24/7 support
    copy right
    2026 All Right Reserved