Single-channel pipettors are adjustable-volume, air-displacement instruments for aspirating and dispensing 0.1 µL to 5,000 µL in individual reactions, available in manual mechanical (spring-piston) and electronic (motorised, programmable) configurations from Eppendorf Research Plus, Gilson PIPETMAN, and Rainin Pipet-Lite product lines. Volume ranges span P2 (0.2–2 µL) through P5000 (1,000–5,000 µL); each instrument is individually ISO 8655-calibrated at the factory and field-recalibratable.
MBP Inc. supplies single-channel pipettors to research and clinical labs across the USA and Canada, with specialist support for procurement teams at institutions including Vanderbilt University and MD Anderson Cancer Center. Contact customerservice@mbpinc.net to request a quote today!
Showing 1 to 12 of 18 results
A single-channel pipettor is the single most widely used liquid handling instrument in molecular biology, cell biology, and clinical research. It transfers precise volumes between 0.1 µL and 5,000 µL, one well or tube at a time, using an air-displacement piston mechanism. The piston creates a partial vacuum that aspirates liquid into a disposable tip; advancing the piston fully dispenses the liquid. A spring-loaded tip ejector releases the used tip without hand contact for contamination control. Manual models depend on finger force and offer simple, battery-free operation; electronic models add programmable aspiration/dispensing speeds, multi-dispense modes, and up to 5 custom pipetting programs. A set of four manual single-channel pipettors (P10, P20, P200, P1000) covers 95% of molecular biology liquid handling; add electronic models for high-throughput repetitive work.
Adjustable volume single-channel pipettors for flexible workflows
Fixed volume pipettors for repeatable dispensing tasks
Mechanical pipettors for standard lab use
Ultra-low volume micropipettors for precise µL handling
Wide-range pipettors covering µL to mL volumes
Autoclavable pipettors for sterile environments
Lightweight ergonomic pipettors for long sessions
Volume Range: Build a Complete Bench Set
A standard four-pipettor bench set covers P10 (1–10 µL), P20 (2–20 µL), P200 (20–200 µL), and P1000 (100–1,000 µL). For sub-microliter work (sequencing, single-cell), add a P2 (0.2–2 µL). For large-volume dispensing (media prep, column loading), add a P5000 (1,000–5,000 µL). Avoid selecting a volume range that places your target dispense below 20% of the maximum — accuracy degrades at the low end of any range.
Manual vs Electronic
Manual single-channel pipettors (Eppendorf Research Plus, Gilson PIPETMAN Classic, Rainin Pipet-Lite XLS+) are the standard for routine lab work: field-calibratable, autoclavable, and requiring no power source. Electronic single-channel pipettors (Eppendorf Research Pro, Rainin Pipet-Lite XLS+ Electronic) add: programmable aspiration/dispense speed (5 speeds), multi-dispense (repeat pipetting) mode, mix mode, dilution mode, and backlight LCD volume display. Electronic models reduce hand fatigue in workflows exceeding 200–300 tip changes per day.
Tip Compatibility
Three tip systems cover the market: standard conical (universal fit — fits Eppendorf Research Plus, Gilson PIPETMAN, Rainin non-LTS, Thermo, Sartorius/BioHit); Rainin LTS cylindrical (requires LTS-specific tips — lower force insertion); Eppendorf epT.I.P.S. proprietary (tightest fit for Eppendorf instruments). Select the tip system that matches your pipettor purchase and existing tip inventory before committing to a brand.
Autoclavability and Chemical Resistance
Manual pipettors from Eppendorf, Gilson, and Rainin have fully autoclavable lower sections (121°C, 15 psi, 15 min). Electronic pipettors have autoclavable nose cones only — the electronic module cannot be autoclaved.
Calibration and Service
All single-channel pipettors are factory-calibrated per ISO 8655. Field recalibration tools are available for Eppendorf, Gilson, and Rainin to perform in-lab gravimetric verification without external service.
ISO 8655 Part 2 accuracy spec for a 200 µL air-displacement pipettor: ±0.8 µL systematic error, ≤0.3 µL random error (Eppendorf Research Plus specification at 200 µL). Most manual pipettors weigh 70–120 g; electronic models weigh 150–220 g. Operating temperature range: typically 15–40°C. Eppendorf Research Plus, Gilson PIPETMAN Classic, and Rainin Pipet-Lite XLS+ LTS remain the three dominant single-channel pipettor platforms in North American research labs.