Product Filters

Microcentrifuges for DNA/RNA Extraction, Protein Pelleting, and Spin-Column Kits

 

Microcentrifuges spin 0.2–2.0 mL microtubes and PCR strips at 10,000–21,000 ×g in a fixed-angle rotor—the required force for nucleic acid kit spin-column steps (10,000–16,000 ×g), ethanol-precipitation DNA/RNA pelleting, and bacterial harvesting. They cannot be replaced by a minicentrifuge (6,000 RPM / 2,000 ×g). MBP is a registered vendor to Howard Hughes Medical Institute, MD Anderson Cancer Center, and Vanderbilt University.

Contact customerservice@mbpinc.net to compare microcentrifuge models and request pricing, availability, or institutional quotes.

Microcentrifuge

Per Page:
Sort By:
Tube Adapter, hold 96 x 0.2ml or 8 and 12 position PCR strips, 2/pk.
List Price:
USD111.91
Online Price:
USD79.94
Your Price:
Work Station Rack for 50 x 5ml tubes
List Price:
USD98.83
Online Price:
USD70.59
Your Price:
Z167-M Microcentrifuge
List Price:
USD3,688.61 - USD3,688.61
Online Price:
USD2,634.72 - USD2,634.72
Your Price:
Z207-M Microcentrifuge
List Price:
USD4,456.23 - USD4,456.23
Online Price:
USD3,183.02 - USD3,183.02
Your Price:
Z216 Microcentrifuges
List Price:
USD4,730.22 - USD9,705.31
Online Price:
USD3,378.73 - USD6,932.37
Your Price:
myFuge™ MiniCentrifuges (8 place) with 2 rotors
List Price:
USD461.38 - USD461.38
Online Price:
USD329.56 - USD329.56
Your Price:
GCM Refrigerated Microcentrifuge Series
List Price:
USD9,776.83 - USD9,776.83
Online Price:
USD6,983.45 - USD6,983.45
Your Price:

Showing 37 to 43 of 43 results

What Are Microcentrifuges?

 

Microcentrifuges are compact, high-speed benchtop centrifuges designed specifically for 0.2–2.0 mL microtubes and PCR strips, operating at 10,000–21,000 ×g in a fixed-angle rotor. They are the primary centrifugation instrument in molecular biology, biochemistry, and clinical molecular diagnostics labs: nucleic acid pellet formation after ethanol precipitation, spin-column DNA/RNA extraction and PCR cleanup steps (typically specified at 10,000–16,000 ×g for 30–60 seconds), cell debris clearance from lysates, protein precipitation supernatant recovery, and brief sample clarification before downstream analysis. Standard benchtop microcentrifuges reach 14,000–15,000 RPM (16,000–21,000 ×g), while high-speed models reach up to 21,000 RPM and approximately 31,000 ×g. Refrigerated variants maintain 0–4°C for temperature-sensitive workflows.

 

What You Will Find:

 

  • High-Speed Microcentrifuges: For faster sample processing
  • Refrigerated Microcentrifuges: For temperature-sensitive handling
  • Benchtop Microcentrifuge Systems: For routine lab working
  • 5D Digital Microcentrifuge: With customizable time and speed options
  • Mini Microcentrifuges: Compact units for rapid spin-down tasks
  • MC-24 High-Speed Microcentrifuge: Features touch screen control and high speed
  • Microplate Centrifuges: Developed for PCR plates and strip formats
  • Microcentrifuge Accessories: For expanded tube flexibility and compatibility

 

How to Choose a Microcentrifuge

 

Maximum RCF vs. Protocol Requirements

Most spin-column kit protocols specify 10,000–16,000 ×g. A standard microcentrifuge reaching 14,000–16,000 ×g covers these requirements. If your lab performs alcohol-precipitation DNA/RNA pelleting (12,000–16,000 ×g) or virus concentration steps (20,000+ ×g), choose a model reaching at least 16,000 ×g. High-speed models reaching 21,000–31,000 ×g are available for specialized applications.

Rotor Tube Positions and Capacity

Most microcentrifuge rotors hold 12–24 × 1.5/2.0 mL tubes per run. Laboratories processing larger batches benefit from 24-position rotors, while smaller research groups may find 12-position models sufficient. Confirm that adapters for 0.5 mL and 0.2 mL tubes are available if required by your workflows.

Refrigerated vs. Ambient Temperature

Refrigerated microcentrifuges are recommended for RNA extraction, protein stability studies, cell viability applications, and any protocol requiring 4°C centrifugation. Standard room-temperature models are suitable for routine DNA extraction and PCR cleanup procedures.

Noise Level and Footprint

Modern brushless DC motor microcentrifuges typically operate at ≤52 dB, making them quieter than older brush-motor systems. Most units occupy 200–300 mm of bench width, so confirm that sufficient clearance is available when the lid is fully open.

Safety Features

Essential safety features include lid-lock mechanisms, imbalance detection, and over-speed protection. Laboratories handling infectious materials should verify that aerosol-tight sealed rotor lids are available for the selected model.

 

Specifications Context

 

The standard spin-column step in most commercial DNA/RNA extraction kits specifies 10,000–16,000 ×g for 30–60 seconds. Always confirm the rotor's maximum RCF from manufacturer specifications, since RPM values alone do not account for differences in rotor radius.

Microcentrifuge rotors are typically fixed-angle designs positioned at approximately 45°, providing efficient pelleting and short sedimentation paths. Aerosol-tight sealed lids allow safe handling of BSL-2 samples and other applications requiring biocontainment. Modern brushless DC motors offer quieter performance, improved speed accuracy, and longer service intervals than legacy brush-motor systems.

Your search for high-performance microcentrifuges is over. Contact now with the expert team at Molecular Biology Products Inc. and get the right microcentrifuge for your lab today.

FAQ

A microcentrifuge is a compact benchtop centrifuge designed for 0.2–2.0 mL microtubes and PCR strips, operating at 10,000–21,000 ×g in a fixed-angle rotor. It is used daily in molecular biology for nucleic acid pellet formation after ethanol precipitation, spin-column kit steps (DNA/RNA extraction, PCR cleanup—typically 10,000–16,000 ×g for 1 min), cell debris removal from lysates, protein precipitation supernatant recovery, and brief clarification before downstream analysis.
A microcentrifuge operates at 10,000–21,000 ×g (approximately 14,000–21,000 RPM) with a variable-speed motor, programmable timer, and the force to complete spin-column kit steps and pellet bacterial cells. A minicentrifuge (personal or pulse centrifuge) runs at a fixed 6,000 RPM (~2,000 ×g) and is suited only for quick condensate spin-downs and PCR strip collection—it cannot complete nucleic acid extraction or protein precipitation protocols that specify 10,000 ×g or higher. A microcentrifuge replaces a minicentrifuge for high-force work; a minicentrifuge does not replace a microcentrifuge.
Standard benchtop microcentrifuges reach 14,000–15,000 RPM, generating 16,000–21,000 ×g depending on the rotor radius. High-speed microcentrifuge models reach up to 21,000 RPM and ~31,000 ×g. Most molecular biology kit protocols specify spin-column steps at 10,000–16,000 ×g for 30–60 seconds; microcentrifuges at 14,000–15,000 RPM comfortably reach these targets. Always confirm the rotor's maximum rated RCF before applying the maximum RPM setting.
Microcentrifuges accept 1.5 mL and 2.0 mL microtubes (Eppendorf-style) as primary formats, with tube adapters for 0.5 mL and 0.2 mL individual PCR tubes. Some models include or optionally accept rotors for 5.0 mL snap-cap tubes. Most microcentrifuge rotors are fixed-angle, holding 12–24 tube positions at 45°; some high-capacity models hold up to 36 × 0.5 mL tubes in a dedicated rotor.
A refrigerated microcentrifuge (operating at 0–4°C or lower) is necessary when processing temperature-sensitive samples: RNA extraction (RNase activity increases at room temperature), protein work where enzymatic activity or protein stability requires cold conditions, cell viability assays, and any protocol that explicitly specifies 4°C centrifugation. Standard room-temperature microcentrifuges are adequate for routine DNA extraction, PCR cleanup, and most short-duration molecular biology spin steps where ambient temperature over a 1–2 minute spin does not affect sample integrity.
Virtually all standard microcentrifuges use fixed-angle rotors (tube angle typically 45°), which maximize RCF per RPM and produce tight pellets at the tube wall—ideal for the pelleting and column-spin applications that define microcentrifuge use. A small number of microcentrifuge models also offer swing-out rotor options for PCR strips or microplates, producing a horizontal layer that is useful for density-gradient work or gentle cell collection from very small volumes. For routine molecular biology, the fixed-angle rotor is the correct and only required configuration.
Key safety features in modern microcentrifuges include an automatic lid lock that prevents opening until the rotor has fully stopped, rotor imbalance detection with automatic shutdown, over-speed protection that cuts power if the rotor exceeds its rated maximum RPM, and aerosol-tight rotor lids or sealed covers for processing infectious or biohazardous samples. All centrifugation of BSL-2 or higher specimens must use a sealed rotor or safety cover to prevent aerosol release from broken tubes.
Some microcentrifuge rotors are autoclavable at 121°C for 20 minutes—Eppendorf fixed-angle aluminum rotors and certain polypropylene adapters are confirmed autoclavable per OEM documentation. However, autoclaving is not universally permitted: polycarbonate components warp at 121°C, and repeated autoclave cycles accelerate fatigue in aluminum rotors. For most labs, surface decontamination with 70% ethanol followed by rinsing with distilled water is the standard inter-run practice. Always consult the OEM manual before autoclaving any rotor component.
We provide the highest quality of products and anytime customer service.
Featured Categories
    online payment
    online payment
    fast delivery
    fast delivery
    technical support
    technical support
    24/7 support
    24/7 support
    copy right
    2026 All Right Reserved