Laboratory incubator accessories are components that customize, maintain, or extend the capacity of CO2 incubators, microbiological incubators, and refrigerated incubators - including stainless steel shelving, humidity water trays, CO2 sensor replacement modules, door seals, and interior racks for culture flasks, tubes, and microplates. They allow a single incubator unit to be reconfigured for different sample types, maintained in calibration, and kept in compliance with lab quality standards. 

MBP provides direct procurement support for incubator accessories with purchase orders for research institutions across the USA and Canada. Request a quote for lab incubator accessories and replacement parts for maintenance, calibration, and capacity expansion by contacting customerservice@mbpinc.net.

Incubator Accessories

Per Page:
Sort By:
Extra Shelf 10.5 x 8"
List Price:
USD91.44
Online Price:
USD65.31
Your Price:

Showing 1 to 1 of 1 results

What Are Lab Incubator Accessories?

 

Laboratory incubator accessories are replacement components, add-on attachments, and optional modules that extend the function of a CO2 incubator, microbiological incubator, shaking incubator, or refrigerated incubator beyond its out-of-the-box configuration. They fall into three broad groups: (1) interior organization (shelving, racks, rotisseries, and slides that configure usable chamber space for specific vessel types); (2) maintenance and calibration (CO2 sensor modules, humidity trays, HEPA filter assemblies, door gaskets, and temperature probes that keep the incubator in specification over time); and (3) contamination control (UV light replacement bulbs, anti-corrosion coating kits, and decontamination accessories that reduce microbial contamination risk in multi-user incubators). Using genuine replacement parts is important for CO2 sensors and HEPA filters in particular, as third-party substitutes may not meet the accuracy or fit specifications required for regulated laboratory workflows. Incubator accessories fall into three categories: organization (shelves, racks), maintenance (sensors, filters, gaskets), and contamination control (UV lamps, decontamination kits); buy the first two on a scheduled basis and the third on an as-needed basis.

 

What You Will Find:

 

  • Extra plastic shelving provides a 10.5 x 8" surface area, perfect for adding a tier of storage for non-autoclavable tasks.

  • Precision-fit design ensures the shelf slides perfectly into your H2200 series units for immediate use without any complicated setup.

 

How to Choose Incubator Accessories

 

Shelving and interior organization

Stainless steel shelves are the most common incubator accessory, adding usable positions without a new unit. Wire-grid shelves allow better air circulation than solid shelves in forced-air incubators, which is important for temperature uniformity when the incubator is fully loaded. Confirm the shelf load rating in kg before stacking heavy culture bottles on a single shelf. Tube racks, slide holders, rotisseries, and microplate stacking frames are available for specific vessel formats.

CO2 sensor modules

CO2 incubators use either thermal conductivity (TC) or infrared (IR) sensors to measure CO2 concentration. TC sensors are less expensive but drift over time and require recalibration after each door opening. IR sensors are more stable, respond faster, and are preferred for high-frequency-access incubators. Replacement CO2 sensor modules are model-specific; always reference the exact incubator model number when ordering.

HEPA filters and air handling

Incubators with forced HEPA-filtered air circulation require periodic filter replacement (typically every 6 to 12 months under continuous use) to maintain the contamination barrier. A clogged HEPA filter reduces airflow, compromises temperature uniformity, and eventually trips an alarm. Replace on the manufacturer's recommended schedule, not on a reactive basis.

Door gaskets and seals

Door gaskets maintain the CO2 and humidity environment inside the chamber. Worn or cracked gaskets allow CO2 leakage, requiring the incubator to run the CO2 supply continuously and potentially causing pH drift in cultures. Inspect door seals quarterly and replace annually or at the first sign of deformation. Gaskets are model-specific; order using the exact incubator model number.

Humidity trays and water pans

CO2 incubators rely on an open water pan to maintain 90% to 95% relative humidity. Clean and refill the humidity tray weekly with sterile deionized water to prevent fungal and bacterial contamination of the water reservoir. Copper water pans (available for some models) reduce microbial growth in the tray compared to stainless steel.

 

Specifications Context

 

When sourcing replacement parts, always use the incubator manufacturer's part number, not just a generic description. Extra shelves, CO2 sensors, HEPA filters, and door gaskets from third-party suppliers may not meet the dimensional or performance tolerances of the original equipment. For incubators operating under GLP, GMP, or ISO 17025 frameworks, use only manufacturer-qualified replacement parts and document each replacement in the equipment logbook. Temperature probes used for incubator calibration verification should be traceable to NIST or equivalent national standards. 

 

Need a bit more room for your research? Check out our shelf options and reach out to the MBP team for a friendly quote today.

FAQ

Laboratory incubator accessories include stainless steel shelves and wire-grid shelf inserts for interior organization; CO2 sensor replacement modules (thermal conductivity or infrared type); HEPA filter elements for air circulation systems; door gaskets and seals; humidity water trays; UV lamp replacement bulbs for decontamination; temperature probe kits; and vessel-specific accessories such as tube racks, rotisseries, microplate stacking frames, and slide holders.
HEPA filter replacement intervals vary by manufacturer, use frequency, and lab environment, but most manufacturers recommend replacement every 6 to 12 months under continuous use. A clogged HEPA filter reduces airflow through the chamber, degrades temperature uniformity, and increases contamination risk. Replace on the manufacturer's scheduled interval rather than waiting for an alarm; many incubators include a filter-life indicator. Always use the manufacturer-specified filter element to maintain rated particle retention efficiency.
Thermal conductivity (TC) sensors measure CO2 by detecting changes in the thermal properties of the chamber gas; they are inexpensive but drift after each door opening and require longer recovery time. Infrared (IR) sensors measure CO2 by detecting infrared light absorption at a CO2-specific wavelength; they are more accurate, respond faster after door events, and are preferred for frequently accessed incubators or where tight pH control is critical. Replacement CO2 sensor modules are model-specific and must match the incubator's original sensor type.
Key contamination prevention practices include: cleaning the humidity water tray weekly with sterile deionized water (and using a copper pan if available); running the manufacturer's dry-heat decontamination cycle (180 degrees C for 5 to 8 hours, if supported) quarterly or after any contamination event; replacing HEPA filter elements on schedule; inspecting door gaskets for cracks and replacing annually; and assigning dedicated shelf space per project. Antifungal agents in the humidity tray water are sometimes used but can confound sensitive cell culture results.
Yes, most incubator manufacturers offer additional stainless steel or wire-grid shelves as accessories. Confirm that the additional shelf matches the model's bracket slot pattern and that the total load per shelf (culture vessels plus media weight) does not exceed the shelf's rated capacity in kg. Adding shelves to a nearly full incubator can also reduce airflow and degrade temperature uniformity -- leave at least 20% of chamber volume as open space for adequate circulation.
Inspect the door gasket quarterly for visible deformation, cracking, or compression set (where the seal no longer springs back after closing). Functional signs of a failing gasket include CO2 recovery time increasing after door openings, CO2 consumption rising without a change in usage pattern, or condensation forming on the exterior of the door frame. Replace the gasket at the first sign of these issues or annually as preventive maintenance. Use only the manufacturer-specified gasket part for your incubator model.
Most incubator accessories are model-specific. CO2 sensor modules, HEPA filter cartridges, door gaskets, and temperature probes are engineered to exact dimensions and specifications for each incubator model and should be ordered using the manufacturer's part number. Stainless steel shelves and wire racks are also sized to chamber dimensions. Tube racks, rotisseries, and microplate frames may fit a range of incubators with the same internal chamber depth and shelf bracket spacing, but verify fit before ordering.
Yes. MBP supports purchase order procurement for incubator accessories and replacement parts for US and Canadian research institutions. MBP is a registered vendor for Howard Hughes Medical Institute, Vanderbilt University, and MD Anderson Cancer Center. For specific part numbers, compatibility, and quote requests, contact MBP's team via the contact page or Quick Order portal with your incubator model number.