Nano spectrophotometer accessories support routine instrument maintenance and operation with replacement cuvettes for cuvette-based measurements, pedestal reconditioning solutions to maintain measurement performance, and replacement printer paper for instruments with integrated printers. Always select accessories compatible with your specific instrument model.
MBP provides direct procurement support for nano spectrophotometer accessories for US and Canadian research laboratories. Request a quote for replacement cuvettes, pedestal maintenance supplies, and compatible accessories by contacting customerservice@mbpinc.net.
Showing 1 to 3 of 3 results
Nano spectrophotometer accessories maintain measurement accuracy, extend the instrument's application range, and support compliance in regulated laboratory environments. They fall into three categories: consumables (cleaning supplies used between every sample measurement), application accessories (microvolume cuvette adapters, fluorometry modules, and assay reagent kits that expand measurement capability), and qualification and compliance accessories (calibration verification kits, performance qualification documentation packages, and software modules for GLP/21 CFR Part 11 data integrity). Cleaning consumables are the highest-turnover accessory type and the most critical for measurement quality: residual sample on the measurement pedestal between readings causes carryover, elevated A260/A280 ratios from nucleic acid contamination, and falsely elevated protein concentrations. Instrument-specific lint-free wipes (not standard lab tissues, which leave fibers) are required for a clean wipe-down of the pedestal between samples. The single most impactful accessory for nano spectrophotometer accuracy is the correct lint-free wipe used between every sample and every blank; inadequate pedestal cleaning between reads is the leading cause of inaccurate measurements.
Specialized 0.5mL tubes packaged in sets of 250, engineered to ensure clear light paths for highly sensitive fluorometric assays.
High-quality replacement cuvettes for traditional macro-volume spectroscopy verification alongside microvolume testing.
Formulated explicitly for SmartDrop systems to provide precise, high-sensitivity fluorometric nucleic acid concentration measurements.
A vital optical maintenance formula that restores hydrophobic properties to the pedestal surface, ensuring perfect sample droplet formation.
Replacement thermal paper sets to keep your automated internal printers operating for immediate on-bench data logging.
Pedestal cleaning wipes and tissues
Optical-grade, lint-free wipes specifically designed for nano spectrophotometer pedestals are the primary consumables. Standard laboratory tissues (Kimwipes) are adequate but may leave very fine fibers that accumulate on the fiber pedestal over time. Instrument-specific wipes designed for the pedestal geometry (flat or curved arm) ensure complete sample removal without scratching the optical surface. Wipe down both the upper and lower pedestal surfaces after every measurement and after every blank. Replace wipes with clean ones between each sample to prevent cross-contamination.
Microvolume cuvette adapters
Microvolume cuvette adapters (such as a micro-cuvette or TrayCell-type accessory) allow nano spectrophotometers with a macro-cuvette port to measure sample volumes of 0.5 to 50 microliters in a path length of 1 to 10 mm. They are used when the sample concentration is below the direct pedestal measurement range (below 2 ng/microliter for dsDNA), and a longer path length is needed to produce measurable absorbance. Confirm that the cuvette adapter is compatible with the specific cuvette measurement mode of the nano spectrophotometer model.
Calibration verification kits
Calibration verification kits contain certified reference standards (solutions of known absorbance at defined wavelengths) used to verify that the instrument's wavelength accuracy and photometric response are within specification. These kits are required for laboratories operating under GLP, ISO 17025, or USP spectrophotometric requirements. Standards include NIST-traceable holmium oxide solution (wavelength calibration standard) and potassium dichromate solution (photometric linearity standard). Verification should be performed at defined intervals specified in the laboratory's quality management system.
Fluorometry assay kits and tubes
Nano spectrophotometers with an integrated fluorometry mode require compatible fluorometric assay kits (high-sensitivity DNA, RNA, or protein quantification assay reagent sets) and appropriate assay tubes or microplates for the fluorometry measurement position. These kits work on the same principle as Qubit-type assays: a fluorescent dye that binds specifically to dsDNA, ssDNA, or RNA produces a signal proportional to analyte concentration. Confirm the kit is specified for the instrument's fluorometry mode and measurement geometry.
Software licenses and validation modules
For regulated environments (pharmaceutical QC, GMP testing, ISO 17025-accredited labs), software licenses that enable 21 CFR Part 11 compliance (audit trails, electronic signatures, data integrity controls) and IQ/OQ/PQ documentation packages are available for most research-grade nano spectrophotometers. These validation packages contain installation qualification (IQ), operational qualification (OQ), and performance qualification (PQ) test scripts and acceptance criteria for the specific instrument model. Confirm the validation package version is compatible with the installed software version before purchase.
Pedestal optical surfaces on nano spectrophotometers are sapphire or quartz fiber, materials that are resistant to most laboratory solvents and cleaning agents but susceptible to physical abrasion from hard particles in standard tissues. Avoid rough tissues, cotton swabs, or abrasive wipes on the pedestal surface. If the pedestal shows persistent background absorbance or drift after normal cleaning, clean with 1:1 isopropanol: water on a lint-free wipe, followed by a dry wipe and a new blank measurement. For stubborn contamination (dried protein, ethidium bromide, phenol), manufacturer-specific cleaning protocols should be followed; using unauthorized solvents on the pedestal can dissolve seals or damage the fiber coating.