Product Filters

Pipettor Accessories for Maintenance and Workflow Support

 

Pipettor accessories are the tools, storage solutions, and maintenance components that extend the service life, accuracy, and organisation of laboratory pipettors — including vertical stands and carousel racks for bench storage, calibration tools for in-lab ISO 8655 verification, O-ring and seal service kits for preventive maintenance, colour-coding rings for instrument identification, and charger stands for electronic models. Manufacturer-matched accessories ensure dimensional compatibility with branded pipette models while universal-format stands accommodate mixed-brand fleets. 

MBP Inc. supplies pipettor accessories for Eppendorf, Gilson, and Rainin instruments, shipping to research labs across the USA and Canada. Contact  customerservice@mbpinc.net  to request a quote today!

Pipettor Accessories

Per Page:
Sort By:
BIOLOGIX PIPETTE STAND. PIPETTE STAND HOLD UP TO 6 PIPETTES IN A LINEAR POSITION. PRICE/CASE
List Price:
USD71.81
Online Price:
USD51.29
Your Price:
Diamond PosiStop Pipettor Starter Packs
List Price:
USD1,024.50 - USD1,143.00
Online Price:
USD731.79 - USD816.43
Your Price:
Pipette Carousel Stand, 6-Place, for Diamond Apex Pipettes
List Price:
USD275.18
Online Price:
USD196.56
Your Price:
Pipette Carousel Stand, 6-Place, for Diamond PosiStop Pipettes
List Price:
USD275.18
Online Price:
USD196.56
Your Price:
Pipette filler, rubber, 1 hand, glass ball valve, EA
List Price:
USD74.49
Online Price:
USD53.21
Your Price:
Pipette, Diamond SeroLogic, Motorized Serological Pipette Controller, Rechargeable
List Price:
USD689.61
Online Price:
USD492.58
Your Price:
Pipettor Racks for Diamond Pipettes
List Price:
USD179.68 - USD197.90
Online Price:
USD128.35 - USD141.36
Your Price:

Showing 1 to 9 of 9 results

What Are Pipettor Accessories?


Pipettor accessories are complementary tools and parts that support correct storage, calibration, maintenance, and identification of laboratory pipettors. Pipettors stored lying flat on a benchtop risk contaminating the nose cone and suffer tip ejector wear; vertical stand storage is the manufacturer-recommended practice for all brands. At a minimum, every lab needs a pipette stand to prevent bench contamination and a calibration tool to verify ISO 8655 accuracy without sending instruments out.

 

What you will find:

 

  • Pipette stands for secure pipettor storage

  • Carousel pipette holders for easy multi-instrument access

  • Pipettor calibration tools for accuracy checks

  • Pipette tip racks and refill systems

  • Pipette filter replacement accessories

  • Pipettor cleaning and maintenance tools

  • Pipette workstation organizers


Key Pipettor Accessory Categories


Pipette Stands and Carousel Racks
Single-position vertical stands store one pipette upright, protecting the nose cone from surface contact. Six-position carousel stands rotate 360° and hold 6 pipettors of mixed sizes — the standard for a molecular biology bench set covering P2, P10, P20, P200, P1000, and P5000. Universal-format carousels (Eppendorf, Gilson, Rainin, Biohit, Thermo) accommodate most standard pipette body diameters; manufacturer-specific stands provide a precision fit. Wall-mount holder systems save bench space in smaller workspaces.

In-Lab Calibration Tools
Gravimetric calibration of a pipettor requires only a calibrated analytical balance (0.0001 g resolution), distilled water, and a calibration tool specific to the pipettor model for adjusting the piston stop. Manufacturer calibration kits (e.g., Gilson Pipetman Calibration Kit, Eppendorf calibration tool) allow in-lab ISO 8655 verification without sending pipettors to an external service. ISO 17025-accredited external calibration services (Gilson, Eppendorf, Rainin) issue certified calibration reports for GLP and regulatory compliance.

O-Ring and Seal Service Kits
Worn O-rings and seals are the most common cause of pipettor inaccuracy and tip leakage after physical damage. Service kits specific to each pipettor model (Gilson PIPETMAN service kit, Eppendorf Research Plus service kit) include O-rings, seals, and small springs for routine preventive maintenance. Gilson recommends preventive maintenance every 1–2 years or whenever calibration verification fails.

Colour-Coding Rings
Colour-coded silicone rings clip onto pipette barrels for quick volume identification, user assignment, or pre/post-PCR segregation in shared labs. Eppendorf ColorTag rings are available in 12 colours and 6 sizes compatible with all Eppendorf pipette models; universal-format rings fit most major brands.

Charger Stands for Electronic Pipettors
Electronic pipettors (Eppendorf Research Pro, Rainin Pipet-Lite XLS+) require charger stands or base docks for overnight charging. Charger stands also serve as storage; the Eppendorf Charger Stand 2 holds and charges a single electronic model on the bench.


Specifications Context


Pipettor stands should be used per all major manufacturer guidelines — Eppendorf, Gilson, and Rainin all specify vertical storage as the correct position to prevent liquid ingress into the piston. ISO 8655 calibration requires distilled water at 20°C, a balance with 0.0001 g resolution, and a minimum of 10 dispenses per volume setting. Eppendorf ColorTag rings are available in 6 sizes covering pipettes from 2 µL to 5,000 µL.  Eppendorf, Gilson, and Rainin offer both in-lab calibration tools and ISO 17025-certified external calibration services. 

Is your workstation as organized as your research? Don’t wait for a pipette to fall or a seal to fail. Connect with the MBP team today to stock up on the essentials that keep your lab running like clockwork.

FAQ

Vertical stand storage prevents liquid from tracking back from the tip into the pipette barrel, which occurs when pipettors are stored horizontally with liquid remaining in the tip. It also keeps the nose cone off bench surfaces, reducing cross-contamination risk and tip ejector wear. All major manufacturers — Eppendorf, Gilson, Rainin — specify vertical storage.
In-lab gravimetric calibration requires a model-specific calibration tool, a calibrated analytical balance with 0.0001 g resolution, distilled water at 20°C, and a minimum of 10 dispenses per volume point. The calibration tool adjusts the piston stop to correct volume delivery. Manufacturers including Gilson, Eppendorf, and Rainin supply in-lab calibration kits for their pipette models.
A pipettor service kit contains model-specific O-rings, seals, and small springs for preventive maintenance. Worn O-rings are the most common cause of pipettor inaccuracy and tip drip after physical damage. Gilson recommends replacing O-rings every 1–2 years or when calibration verification fails; service kits specific to each pipettor model are available.
Colour-coding rings are silicone rings that clip onto the pipette barrel for user identification, volume labelling, and pre/post-PCR segregation in shared labs. Eppendorf ColorTag rings are available in 12 colours and 6 sizes covering 2–5,000 µL models; universal rings fit most major pipette brands including Gilson and Rainin.
Universal pipette stands accommodate most standard pipette body diameters and suit labs with mixed-brand instruments. Brand-specific stands (Eppendorf, Gilson, Rainin) provide a precision fit for each model, minimising rattle and ensuring correct nose cone clearance. Carousel racks in both formats hold 6 pipettors simultaneously for standard bench-set organisation.
Manufacturer guidelines and ISO 8655 best practice recommend preventive maintenance at minimum every 12 months for routine research use — more frequently in high-throughput or GLP environments. Maintenance intervals should also be triggered by calibration failure, visible seal wear, tip drip between aspirations, or any physical impact to the instrument.
Charger stands are model-specific — the Eppendorf Charger Stand 2 is designed for Eppendorf electronic models, Rainin charger docks for Rainin Pipet-Lite XLS+ instruments. Confirm compatibility between the charger stand and your specific electronic pipettor model before purchasing.
ISO 8655 gravimetric calibration requires an analytical balance with a minimum resolution of 0.0001 g (0.1 mg) to achieve sufficient accuracy for small-volume dispenses (≤20 µL). A 0.001 g balance is adequate for volumes above 200 µL but introduces unacceptable uncertainty for microlitre-range pipettor verification.
MBP Inc. accepts purchase orders for pipettor accessories — stands, calibration tools, service kits, and colour-coding rings — and offers a Quick Order tool for recurring lab items. MBP is a registered vendor at Vanderbilt University, Howard Hughes Medical Institute, and MD Anderson Cancer Center.
Wall-mount pipette holders are available as single-position and multi-position formats for space-constrained labs. They mount on walls, cabinets, or fume hood panels and hold pipettors in the correct vertical storage orientation, freeing bench surface for active work areas.
We provide the highest quality of products and anytime customer service.
Featured Categories
    online payment
    online payment
    fast delivery
    fast delivery
    technical support
    technical support
    24/7 support
    24/7 support
    copy right
    2026 All Right Reserved