Product Filters

IHC Slides for Immunohistochemistry and Tissue Analysis

 

IHC slides are positively charged borosilicate or white glass microscope slides with a permanent electrostatic surface coating that retains FFPE and frozen tissue sections through heat-induced antigen retrieval (HIER), antibody incubations, and buffer washes. MBP stocks Globe Scientific Diamond White Glass charged slides in 25 × 75 mm format with 90° ground or 45° beveled edges, in nine color-coded frosted-end options, packed 72 or 144 per box, shipping to US, Canadian, and international pathology and research labs.

Need help selecting the right IHC slides for your histology or pathology workflow? — Contact our team at customerservice@mbpinc.net for product recommendations, bulk pricing, and purchasing assistance.

IHC Slides

productListingPage:PER_PAGE:
productListingPage:SORT_BY:

What Are IHC Slides?

 

IHC slides, also known as charged slides or adhesion slides, are microscope slides designed specifically for immunohistochemistry (IHC), histology, cytology, and pathology applications. These slides feature a permanently charged surface that helps tissue sections and cellular samples remain attached during staining procedures, heat-induced epitope retrieval (HIER), antibody incubations, and repeated wash steps.

Globe Scientific Diamond® White Glass charged slides are manufactured from optical-quality white glass and come pre-cleaned and ready to use. They are available with either 90° ground edges or 45° beveled safety corners and are offered in multiple frosted-end color options to simplify specimen identification and laboratory workflow management.

Charged IHC slides are essential for FFPE tissue sections, frozen sections, and cytospin preparations because they help prevent tissue loss during staining and antigen retrieval procedures.

 

What you will find:

 

  • Human breast cancer control slides

  • FFPE kidney cancer tissue sections

  • Human brain tissue microarray slides

  • Paraffin-embedded colon cancer sections

  • Intestine cancer diagnostic slides

  • Positive charged IHC control slides

  • Formalin-fixed stomach cancer samples

  • Microtome-sectioned pathology slides

 

How to Choose IHC Slides

 

Hydrophobic vs Hydrophilic Surface

Most charged IHC slides use a hydrophobic positively charged surface, making them suitable for routine FFPE tissue staining, frozen sections, and cytology applications. These slides provide reliable tissue adhesion during manual immunohistochemistry workflows.

Hydrophilic charged slides are commonly used with automated staining systems where uniform reagent distribution across the slide surface is important. These specialty slides are often selected for automated IHC platforms and high-throughput laboratory workflows.

 

Adhesion Strength

Standard charged slides provide strong tissue adhesion suitable for most routine immunohistochemistry applications, including common antigen retrieval protocols and standard staining procedures.

For challenging specimens such as fragile frozen sections, decalcified tissues, or protocols involving extended high-temperature antigen retrieval, laboratories may choose specialty slides designed to provide enhanced adhesion performance.

 

Edge Style

Slides with 90° ground edges provide a smooth finish that works well with automated staining and coverslipping systems.

Slides with 45° beveled safety corners help reduce the risk of cuts during handling and are often preferred in laboratories that process large numbers of slides daily.

 

Frosted Ends and Color Coding

Frosted labeling areas allow specimen information to be written directly on the slide. Color-coded frosted ends can help distinguish patient samples, staining batches, and laboratory workflows. Multiple color options are available to support organization in busy pathology and histology laboratories.

 

Packaging Options

IHC slides are available in various box and case quantities to accommodate laboratories of different sizes. High-volume pathology laboratories often purchase slides in case quantities to ensure a consistent supply for routine diagnostic and research work.

 

IHC Slide Options

 

Globe Scientific Diamond Charged Slides feature a positively charged hydrophobic surface and are commonly used for routine FFPE immunohistochemistry, frozen sections, and cytology preparations.

 

Color-Coded Charged Slides provide the same adhesion performance while adding colored frosted labeling areas for improved specimen tracking.

 

Hydrophilic Charged Slides are designed for automated immunohistochemistry systems and applications requiring optimized reagent distribution.

 

Standard Uncharged Slides are suitable for routine histology, H&E staining, blood smears, and general microscopy procedures where enhanced adhesion is not required.

 

Specifications Context

 

Globe Scientific Diamond White Glass charged microscope slides are manufactured from optical-quality white glass and feature a permanent positive surface charge. Standard dimensions are approximately 25 × 75 mm with a thickness of about 1 mm. Slides are supplied pre-cleaned and ready for laboratory use.

Available options include 90° ground edges or 45° beveled safety corners, along with frosted-end labeling areas in white, blue, red, green, yellow, orange, aqua, pink, and lavender.

Packaging formats include boxes containing 72 or 144 slides, with larger case quantities available for high-volume laboratories. Globe Scientific products are manufactured under ISO 9001:2015 quality standards.

As of 2026, MBP stocks charged microscope slides in multiple colors and packaging options. Contact MBP for current availability, pricing, and bulk-order information.

Ready to streamline your pathology validation? Request a quote from the helpful team at MBP today.

FAQ

IHC slides are positively charged glass microscope slides used in immunohistochemistry to retain tissue sections during the multi-step staining process. The permanent positive charge creates electrostatic attraction between the glass surface and the negatively charged tissue section, preventing detachment during heat-induced antigen retrieval (HIER), antibody incubations, and buffer washes — steps that reliably cause section loss on uncharged slides.
MBP stocks Globe Scientific Diamond White Glass positively charged microscope slides in 25 × 75 mm format, approximately 1 mm thick, pre-cleaned and ready to use. Available with 90° ground or 45° beveled safety-corner edges, in nine frosted-end color options: white, blue, red, green, yellow, orange, aqua, pink, and lavender. Packed 72 or 144 per box.
Hydrophobic positively charged slides (Globe Scientific Diamond) are the standard choice for manual FFPE IHC, frozen sections, and PAP smears. Hydrophilic positively charged slides are optimized for automated IHC platforms (Ventana/Roche Benchmark, Leica Bond) — the hydrophilic surface eliminates trapped water beneath tissue sections during drying, improving section flatness and reagent coverage on automated staining platforms.
Globe Scientific Diamond White Glass charged slides are designed to retain tissue sections through standard HIER protocols — citrate buffer at pH 6.0 or EDTA buffer at pH 9.0, heated to 95–99 °C for 20–40 minutes in a pressure cooker, water bath, or microwave. For very difficult tissues or extended HIER protocols (> 60 minutes at high temperature), consider slides with very strong adhesion ratings; contact MBP to confirm available options.
Globe Scientific Diamond White Glass charged slides are available with frosted ends in nine colors: white, blue, red, green, yellow, orange, aqua, pink, and lavender. Color-coded frosted ends support patient and sample batch tracking in multi-protocol histology and pathology departments. Contact MBP to confirm which colors are currently in stock.
Globe Scientific Diamond White Glass charged slides are packed 72 slides per box in the standard format, with 1,440 slides per case (20 boxes). A 144-slide-per-box format is also available, yielding 288 slides per case. Contact MBP for current case pricing and color availability.
Globe Scientific Diamond White Glass hydrophobic charged slides are compatible with manual IHC protocols and many automated staining platforms. For Ventana/Roche Benchmark and Leica Bond automated systems, a hydrophilic positively charged slide surface is recommended for optimal reagent distribution and minimal background — contact MBP for hydrophilic charged slide availability.
MBP accepts institutional purchase orders for IHC slides and all glassware. MBP is a registered vendor to Howard Hughes Medical Institute, Vanderbilt University, and MD Anderson Cancer Center. Use the Quick Order portal for reorders or contact the MBP team for PO setup, volume pricing, and standing-order arrangements for high-throughput pathology departments.
90° ground edges are compatible with automated slide coverslipper clips and stainer racks — preferred for high-throughput labs using automated equipment. 45° beveled safety-corner edges reduce the risk of cuts during manual slide handling — preferred when technologists handle large numbers of slides per shift without automated processing. Both edge styles are available in Globe Scientific Diamond charged slides from MBP.
Globe Scientific is ISO 9001:2015 certified, and their Diamond White Glass charged slides are manufactured under this quality management system. Slides are pre-cleaned and inspected before packing. Contact MBP for lot documentation or technical specifications.
We provide the highest quality of products and anytime customer service.
LinkedIn
Featured Categories
online payment
online payment
fast delivery
fast delivery
technical support
technical support
24/7 support
24/7 support
copy right
2026 All Right Reserved