Across International IH series mid-frequency induction heaters are designed to operate between 30 and 80 kHz. Mid-frequency heaters are excellent for small parts heating, cutting, diamond tool brazing, soldering copper plumbing fittings, auto parts heat-treating, annealing of stainless steel containers and more.
Mid-frequency induction heaters are the simplest in terms of design and implementation. With their low cost of ownership and maintenance, they are the most popular and reliable machines. The 15kW models are especially popular for their large power capacity and small footprint at an affordable price. This makes them standard equipment for many factories, labs and workshops where 230V AC is available.
Safety
- Overvoltage protection: machine shuts down when input voltage is over 245V. Overvoltage light will turn on and buzzer will sound continuously. Alarm and light shut off automatically when voltage goes below 245V.
- Overheat protection: if sensor detects heat radiatortemperature is over 55C, machine will shut down, overheat light will turn on and buzzer will sound continuously. Increase water pressure or lower water temperature until alarm goes off itself.
- Overcurrent/malfunction protections: machine will shut down, indicator light turned on and buzzer sounds continuously if one of these situations occurs:
- One of the machine parts becomes overheated
- Interfering signal detected
- Short circuit between work pieces and induction coils
- Machine malfunctions
- Induction coils touching each other
- Input voltage is too low
- Low water pressure protection: if water pressure goes below 29 PSI, machine will shut down, water protection light will turn on and buzzer will sound continuously.
IMPORTANT
- Always wear protective gear and goggles when operating the machine. Crucibles must be covered all the time during operation. Across International is not responsible for any damage caused by misuse.
- Do not run no-load operation for a long period of time, it might cause damage to the machine.
- Circulating water must be pure, clean and below 45C.
- Machine must be grounded properly all the time during operation.
- Do NOT use single-turn coil if coil diameter is smaller than 4 inches, it will cause high frequency damage to the machine.
- Thread tape (or related material) is absolutely prohibited during installation of induction coils.
IH25A
Overview
Note: This model only available in 460-480 volt three phase.
Across International IH series mid-frequency induction heaters are designed to operate between 30 and 80 kHz. Mid-frequency heaters are excellent for small parts heating, cutting, diamond tool brazing, soldering copper plumbing fittings, auto parts heat-treating, annealing of stainless steel containers and more.
Mid-frequency induction heaters are the simplest in terms of design and implementation. With their low cost of ownership and maintenance, they are the most popular and reliable machines. The 15kW models are especially popular for their large power capacity and small footprint at an affordable price. This makes them standard equipment for many factories, labs and workshops where 230V AC is available.
Safety Features
- Overvoltage protection: machine shuts down when input voltage is over 245V. Overvoltage light will turn on and buzzer will sound continuously. Alarm and light shut off automatically when voltage goes below 245V.
- Overheat protection: if sensor detects IGBT heat sink temperature is over 55⁰C, machine will shut down, overheat light will turn on and buzzer will sound continuously. Increase water pressure or lower water temperature until alarm goes off itself.
- Overcurrent/malfunction protections: machine will shut down, indicator light will turn on and buzzer wil sound continuously if one of these situations occurs:
- One of the machine parts becomes overheated.
- Interfering signal detected.
- Short circuit between work pieces and induction coils
- Machine failures.
- Induction coils touching each other.
- The input voltage is too low.
- Low water pressure protection: if water pressure goes below 29 PSI.
IMPORTANT!!
- Always wear protective gear and goggles when operating the machine. Crucibles must be covered all the time during operation. Across International is not responsible for any injury or damage caused by misuse.
- Do not run no-load operation for a long period of time, it might cause damage to the machine.
- Circulating water must be pure, clean and below 45C.
- Machine must be grounded properly all the time during operation.
- Do NOT use single-turn coil if coil diameter is smaller than 4 inches, it will cause high frequency damage to the machine.
- Thread tape (or related material) is absolutely prohibited during installation of induction coils.
IH15A
Specifications
Max. input current | 32 A (40A single-phase circuit breaker required) |
Power | 208-240V, 50/60Hz, single-phase |
Power distribution cord | 8-gauge 3-conductor Max 40A (8/3 SOOW) |
Output frequency | 30-80 KHz |
Heating/retaining current | 200-600 A (displayed on control panel) |
Max. oscillating power | 15 KW |
Max input power | 7 KW |
Duty cycle | 80% |
Heating/dwelling/cooling timers | 1-99 seconds |
Water pressure | ≥ 29 PSI (0.2 Mpa) you may use tap water and water pump (>1/4HP & >240 Gph) |
Water flow | 0.5-1.3 gallons (2-5 liters) per minute |
Water temperature | 25-30°C |
Induction coil | See detail specs below, we will make coils according to your requirements |
Weight | Unit: 40 Lb, shipping: 58 Lb |
Size | Unit: 19x8x18″, shipping: 21x13x22″ |
Remote foot switch | 7 feet |
Max. melting capacity | 4 Lb (gold, silver, copper), 1 Lb (steel, aluminum) |
IH25A
Specifications
Max. input current | 19 A (25A 3-phase circuit breaker required) |
Power | 460 VAC, 50/60Hz, three phase (380V model available upon request) |
Power distribution cord | 10-gauge 4-conductor Max 25A (10/4 SOOW for 3 PH system) |
Output frequency | 30-80 KHz |
Heating/retaining current | 200-1000 A (displayed on control panel) |
Max. oscillating power | 25 KW |
Max input power | 15 KW |
Duty cycle | 80% |
Heating timer | 1-99 seconds |
Dwelling timer | 1-99 seconds |
Cooling timer | 1-99 seconds |
Water pressure | ≥ 0.2 Mpa (29 PSI) you may use tap water and water pump (>1/4HP & >240 Gph) |
Water flow | 0.5-1.3 gallones (2-5 liters) per minute |
Induction coil | See detail specs below, we will make coils according to your requirements |
Weight | Unit: 60 Lb, shipping: 85 Lb |
Size | Unit: 23x9x18″, shipping: 28x14x26″ |
Remote foot switch | 7 feet |
Max. melting capacity | 7 Lb (gold, silver, copper), 2 Lb (steel, aluminum) |
IH15A
Standard package
Part description | Quantity | Part image |
IH15A induction heater | 1 pc | ![]() |
0-5V Cable | 1 pc | ![]() |
Foot switch (7 ft) | 1 pc | ![]() |
Induction coil Coil # 1 Orientation: Vertical Turns: 3 ID: 76 mm OD: 90 mm Coil # 2 Orientation: Vertical Turns: 3 ID: 50 mm | 2 pcs | ![]() |
Stainless steel hose clamp | 8 pcs | ![]() |
Fuse | 5 pcs | ![]() |
Induction coil adapter (to protect the coil connectors on the machine, good for users who change coils frequently) | 2 pcs | ![]() |
Operation manual | 1 pc | ![]() |
IH25A
Standard package
Part description | Quantity | Part image |
IH25A induction heater | 1 pc | ![]() |
Foot switch (7 ft) | 1 pc | ![]() |
Induction coil: 8mm diameter, 75x300mm IDxL, adjustable height. Coil is insulated to prevent sparks caused by work piece touching the tube. | 2 pcs | ![]() |
Stainless steel hose clamp | 8 pcs | ![]() |
0-5 V Cable | 1 pc | ![]() |
Fuse | 5 pcs | ![]() |
Induction coil adapter (to protect the coil connectors on the machine, good for users who change coils frequently) | 2 pcs | ![]() |
Operation manual | 1 pc | ![]() |